Introduction: TLP-3C 2M Transmission Analyzer is a multi-functional and full-featured digital transmission system test device, designed for the installation test, engineering check and acceptance, daily maintenance of digital networks, mainly performing channel test, alarm analysis, fault finding and signaling analysis. In addition, this instrument further provides various protocol converters with one-way and bi-directional bit error test function. These capabilities make it ideal for field use.
Basic Functions: 1) 2M testing 75Ω and 120Ω line interfaces HDB3 and AMI line codes Out-of-service 2Mb/s, N×64kb/s BER testing “PCM simulator” mode testing Frame data control and monitoring Timelot activity monitoring, FAS, N-FAS, TS16MFO analysis Built-in 64kb/s tone channel listen capability CAS and CCS signaling generation and monitoring Round trip delay measurement APS delay measurement Extensive error and alarm generation VF tone generation and measurement Level measurement Pulse mask measurement Jitter measurements to ITU-T standard O.172 Frequency and offset measurement Clock slip measurement Up to ±999ppm transmit clock deviation Clock source: Internal, Interface or External 2M clock/signal Real-time transmit circuit open/short indication 2) Datacom testing Datacom (V.24, V.35, V.36, X.21, RS-449, RS-485, EIA-530 and EIA-530A) interfaces BER Testing ASYNC BER testing with baud rate 300b/s~38.4Kb/s SYNC BER testing with data rate 300b/s~8Mb/s DTE or DCE emulation SYNC clock source and sense selection Frequency measurement Handshaking signals control and monitoring 3) G.703 CO testing G.703 CO 64kb/s BER testing Octet timing control and monitoring Frequency and offset measurement Clock source: Internal, Interface selectable 4) Protocol converter testing 2M-Datacom SYNC 64k or N×64kb/s BER testing 2M-G.703 CO SYNC 64kb/s BER testing Frequency and offset measurement Handshaking signals monitoring 2M frame data and alarm monitoring 5) Other functions Real-time clock Test pattern: PRBS, Fixed Code and 16-BIT User Word Error injection: Single and Fixed Rate Manual and auto-timer measurement ITU-T G.821, G.826, and M.2100 performance analysis
Features:
Handheld design and easy-to-use
Full-featured measurements to 2M, Datacom
High resolution backlight large LCD screen, with adjustable contrast
Smart navigation mode and multi-language displays
Extensive error and alarm generation, detection and indication
Histograms analysis of alarm and error events
Up to 99 days continuance test performance
Save/Recall of up to 7 user-defined setups and 70 sets of results
Up to 6 hours operation from a single battery charge
Built-in Li rechargeable battery and smart charger circuit
Can be charged with automobile cigarette lighter battery adapter
Ungradable software via an integrated RS232C interface
Test results uploaded, conserved and printed by PC Manager software
Specification:
Item
Description
2M
Internal Clock
2048kb/s ±10ppm
Frequency Deviation
±999ppm
Line Interface
75Ω (Unbalanced), 120Ω (Balanced); High Input Impedance >2KW
Line Code
HDB3, AMI
Framing
Unframed, PCM30, PCM30CRC, PCM31, PCM31CRC
Receive Sensitivity
>-43dB
Tx Clock Source
Internal, Interface and External 2MHz clock or signal
Mô tả
Introduction:
TLP-3C 2M Transmission Analyzer is a multi-functional and full-featured digital transmission system test device, designed for the installation test, engineering check and acceptance, daily maintenance of digital networks, mainly performing channel test, alarm analysis, fault finding and signaling analysis. In addition, this instrument further provides various protocol converters with one-way and bi-directional bit error test function. These capabilities make it ideal for field use.
Basic Functions:
1) 2M testing
75Ω and 120Ω line interfaces
HDB3 and AMI line codes
Out-of-service 2Mb/s, N×64kb/s BER testing
“PCM simulator” mode testing
Frame data control and monitoring
Timelot activity monitoring, FAS, N-FAS, TS16MFO analysis
Built-in 64kb/s tone channel listen capability
CAS and CCS signaling generation and monitoring
Round trip delay measurement
APS delay measurement
Extensive error and alarm generation
VF tone generation and measurement
Level measurement
Pulse mask measurement
Jitter measurements to ITU-T standard O.172
Frequency and offset measurement
Clock slip measurement
Up to ±999ppm transmit clock deviation
Clock source: Internal, Interface or External 2M clock/signal
Real-time transmit circuit open/short indication
2) Datacom testing
Datacom (V.24, V.35, V.36, X.21, RS-449, RS-485, EIA-530 and EIA-530A) interfaces BER Testing
ASYNC BER testing with baud rate 300b/s~38.4Kb/s
SYNC BER testing with data rate 300b/s~8Mb/s
DTE or DCE emulation
SYNC clock source and sense selection
Frequency measurement
Handshaking signals control and monitoring
3) G.703 CO testing
G.703 CO 64kb/s BER testing
Octet timing control and monitoring
Frequency and offset measurement
Clock source: Internal, Interface selectable
4) Protocol converter testing
2M-Datacom SYNC 64k or N×64kb/s BER testing
2M-G.703 CO SYNC 64kb/s BER testing
Frequency and offset measurement
Handshaking signals monitoring
2M frame data and alarm monitoring
5) Other functions
Real-time clock
Test pattern: PRBS, Fixed Code and 16-BIT User Word
Error injection: Single and Fixed Rate
Manual and auto-timer measurement
ITU-T G.821, G.826, and M.2100 performance analysis
Features:
Specification:
Range: -999ppm~+999ppm
Accuracy: ±1Hz
-60dBm~-21dBm, accuracy: ±2.87dBm
-20dBm~+3.14dBm, accuracy: ±0.21dBm
N×64kb/s (N=1~32), 4M, 8Mkb/s